Heat pumps are increasingly popular in Georgetown's mild winters, they're efficient down to about 35ยฐF, and Central Texas rarely sees sustained temperatures below that threshold. ProAir Georgetown services all heat pump brands and configurations, from standard split systems to cold-climate models.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Heat Pump Services We Offer in Georgetown TX

๐Ÿ”ง
Heat Pump Repair

All heat pump repairs, reversing valve, defrost board, auxiliary heat, refrigerant circuit, and electrical components.

๐Ÿ”
Heat Pump Diagnostics

Systematic diagnosis of heat pump issues including heating mode failures, cooling failures, and abnormal operation.

๐Ÿ› ๏ธ
Heat Pump Maintenance

Bi-annual heat pump tune-up, coil cleaning, refrigerant check, electrical testing, and defrost system verification.

๐Ÿ“ˆ
Heat Pump Performance Service

Performance evaluation and optimization for heat pump systems running inefficiently or failing to reach setpoint.

๐Ÿ’จ
Heat Pump Airflow Balancing

Balance airflow distribution from heat pump systems for consistent comfort throughout the home.

๐Ÿ”„
Heat Pump Reversing Valve Diagnostics

The reversing valve switches the system between heating and cooling mode. Failure causes it to lock in one mode, we test and replace as needed.

โ„๏ธ
Heat Pump Defrost Control Board Replacement

Defrost board failure causes ice accumulation on the outdoor coil, we replace faulty boards and verify defrost cycles.

๐Ÿ”ฅ
Heat Pump Base Pan Heater Installation

Prevent ice accumulation in the outdoor unit base pan during Georgetown freeze events.

๐Ÿ”๏ธ
Heat Pump Snow Stand Installation

Elevate the outdoor unit to prevent flooding and ice coverage during rare Georgetown ice storms.

๐Ÿ”ฅ
Auxiliary Heat Control Repair

Aux heat strips provide backup heating below the heat pump's efficiency range, we repair auxiliary heat controls and sequencers.

โ„๏ธ
Heat Pump Defrost Mode Correction

Heat pump stuck in defrost, defrosting too frequently, or not defrosting enough, we calibrate or repair the defrost system.

โšก
Heat Pump Emergency Repair

Same-day emergency heat pump service during Georgetown cold snaps and summer peak cooling periods.

How Auxiliary Heat Staging Works

A heat pump's compressor loses heating capacity as outdoor temperatures drop, and below roughly 30 to 35 degrees Fahrenheit it often can not keep up with the home's heat loss on its own. Auxiliary heat, sometimes called strip heat or electric resistance heat, is a bank of electric heating elements built into the air handler that energizes to make up the difference. On most systems this is controlled by a heat sequencer or the outdoor thermostat, which reads either the outdoor ambient temperature or the discharge air temperature and stages the strips on in steps rather than all at once, both to limit the electrical inrush and to only add as much supplemental heat as is actually needed.

When auxiliary heat control fails, it usually shows up in one of two opposite ways. A stuck or welded relay contact, or a sequencer that fails closed, keeps the strips energized continuously even when the compressor alone could satisfy the thermostat, which drives electric bills up sharply without an obvious comfort complaint. The other failure mode is a blown fuse, tripped high-limit switch, or failed sequencer that never lets the strips engage at all, so the home simply can not reach setpoint during cold snaps even though the compressor is running normally. There is also the emergency heat setting on the thermostat, which manually locks out the compressor and runs on strip heat alone. It is meant as a temporary override when the compressor or reversing valve has failed, not a setting to leave on, and we frequently find it switched on by accident.

Repairing auxiliary heat control starts with confirming the outdoor thermostat or board's ambient sensor is reading accurately, then tracing the W2 and E terminal wiring to the sequencer or heat relay board, testing each stepping relay's coil and contacts, and ohming out the resistance of each heat strip element against the manufacturer's chart. We also check the high-limit safety switch mounted on the strip assembly itself, since a dirty filter restricting airflow across the strips can trip this switch and mimic a control failure. On the electrical side we verify the breaker amperage matches the total kW rating of the strip banks, since older Georgetown homes built before heat pumps were standard sometimes have panels sized without that extra load in mind, and a hard freeze that pushes strips into heavy use can be the first time an undersized circuit gets tested.

Replacement parts vary by what failed: a sequencer or control board typically runs $150 to $450, while a full heat strip element bank replacement runs $200 to $600 depending on the kW rating installed.

Frequently Asked Questions About Auxiliary Heat Control

Why is my heat pump running up my electric bill in winter? +
This is most often a sequencer or contactor stuck in the closed position, keeping the electric strips energized continuously instead of only staging on when the compressor needs help. It can also happen if the thermostat was accidentally switched to emergency heat.
What is the difference between aux heat and emergency heat on my thermostat? +
Auxiliary heat automatically supplements the compressor during very cold weather or when extra recovery heat is needed. Emergency heat manually locks the compressor out entirely and runs on strip heat only, intended as a temporary measure when the compressor or reversing valve has failed.
Why did my heat stop working during a hard freeze? +
A common cause is a tripped breaker from combined heat pump and auxiliary heat amp draw exceeding the panel's capacity, or a failed sequencer that prevents the strips from engaging when the compressor alone can not keep up.
Can a dirty air filter affect auxiliary heat operation? +
Yes. Restricted airflow across the heat strips can trip the high-limit safety switch, which cuts strip heat off as a safety measure and can be mistaken for a control failure.
How do I know if my aux heat strips are actually working? +
You can check by calling for a higher setpoint on a cold day and feeling for a noticeable rise in supply air temperature, or listening for the stepped clicking of the sequencer relays engaging.