Mini-split systems are popular in Georgetown for additions, garages, home offices, and rooms where extending ductwork isn't practical. ProAir Georgetown installs, repairs, and maintains single-zone and multi-zone mini-split systems from all major manufacturers.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Mini-Split Services in Georgetown TX

๐Ÿ—๏ธ
Mini-Split Installation

Complete mini-split installation, line set, electrical, mounting, and commissioning for all zones and room types.

๐Ÿ”ง
Mini-Split Repair

All mini-split repairs: communication errors, drainage issues, compressor failures, and refrigerant leaks.

๐Ÿ› ๏ธ
Mini-Split Maintenance

Annual mini-split service: filter cleaning, coil inspection, drain line flush, and refrigerant verification.

๐Ÿงน
Mini-Split Deep Cleaning

Professional deep cleaning of the indoor air handler, blower wheel, coil, housing, and drain pan.

๐Ÿ’จ
Mini-Split Airflow Balancing

Optimize airflow direction and speed settings for even temperature distribution in the served space.

๐Ÿ—บ๏ธ
Multi-Zone Mini-Split Balancing

Balance refrigerant distribution and operating parameters across multiple indoor units in multi-zone systems.

โฌ†๏ธ
Ceiling Cassette Mini-Split Maintenance

Specialized maintenance for ceiling cassette units, filter, drain, coil, and baffle service.

โฌ‡๏ธ
Floor-Mounted Mini-Split Service

Maintenance and repair for floor-mounted mini-split indoor units including coil and drain service.

๐Ÿ”Œ
Mini-Split Line Set Service

Inspect, repair, or replace mini-split refrigerant line sets and insulation.

๐Ÿ“ฆ
Mini-Split Line Set Cover Installation

Install decorative line set covers for a clean, finished appearance on interior and exterior runs.

๐Ÿ’ง
Mini-Split Condensate Service

Clear blocked drain lines, repair drain pans, and install condensate pumps for difficult drainage situations.

Common Mini-Split Failures We Diagnose

Most mini-split repair calls fall into a handful of recurring categories, and figuring out which one applies determines whether a technician needs 20 minutes or half a day on site. A blinking or coded error on the indoor head's display often points to a communication fault between the indoor and outdoor units, frequently caused by a corroded low-voltage wire connector or a wire nicked during a prior repair rather than an actual component failure. We check the communication wiring and connector integrity first, since replacing a board based on a code alone sometimes fixes nothing if the underlying wiring fault remains.

Compressor problems show up differently than most homeowners expect. Rather than the unit failing to turn on at all, a struggling compressor often runs, and the outdoor fan spins, but the system produces little to no actual cooling, or the outdoor unit hums audibly without the compressor engaging, usually a sign of a failed start or run capacitor rather than the compressor itself. We test capacitors under load before assuming compressor failure, since a $85 to $220 capacitor replacement is a very different repair than a compressor swap.

The electronic expansion valve, the component that meters refrigerant flow into the indoor coil, can stick partially open or closed from age or debris, causing either coil icing from excess flow restriction or poor cooling from too little refrigerant reaching the coil. This looks similar to a low refrigerant charge on a gauge set, so we verify EEV operation and superheat behavior rather than assuming every undercooling complaint is a leak. Circuit boards fail too, most often from power surges during Georgetown's spring and early summer storm season or from moisture intrusion into an outdoor unit's control compartment, and a surge-damaged board typically shows no visible damage at all, only erratic or absent operation.

A refrigerant leak reveals itself through ice forming on the indoor coil, warm air from the vents despite the unit running, or an audible hiss at a fitting when the system starts. We locate leaks with electronic detection or nitrogen pressure testing rather than guessing, since flare fittings, brazed joints, and factory connections all leak differently and each calls for a different repair approach. Many mini-split systems installed during Georgetown's early 2010s construction boom are now reaching 10 to 15 years old, the point where compressor and board failures become more common regardless of how well the system was maintained. Repair costs typically range from $85 for a simple capacitor or wiring fix up to $600 or more for compressor or board replacement.

Frequently Asked Questions, Mini-Split Repair

What does it mean when my mini-split displays a blinking error code? +
Most blinking codes indicate a communication fault between the indoor and outdoor units, often from a corroded or damaged low-voltage wire connector rather than a failed major component.
Can a mini-split compressor be repaired or does it need replacement? +
Compressors themselves are not field-repairable, only replaced. We always confirm the compressor is actually the problem first, since a failed capacitor produces similar symptoms and costs far less to fix.
Why does the outdoor unit hum but not turn on? +
This is usually a failed start or run capacitor unable to supply the compressor with the jolt it needs to start turning. We test capacitors under load before recommending any further repair.
Is a refrigerant leak repairable on a mini-split? +
Most leaks at flare fittings or accessible joints are repairable. We locate the leak with electronic detection or a nitrogen pressure test rather than simply adding refrigerant without fixing the source.
What causes a mini-split to restart repeatedly on its own? +
This can point to a failing circuit board, a sticking expansion valve, or a drain float switch tripping intermittently. We check all three before replacing any single component.