โ„๏ธ Condenser Coil Repair, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Repairing Rather Than Replacing a Coil

Condenser coils develop leaks from a handful of specific causes, and which one applies determines whether repair is even a reasonable option. Physical damage, a bent fin puncture from a fallen branch, a lawn tool strike, or hail impact common during Central Texas spring storms, tends to produce a localized, repairable leak at a single tube. Formicary corrosion, sometimes called ant nest corrosion, is a different and more serious problem where organic acids, often from certain wood products, adhesives, or airborne contaminants, attack the copper tubing wall from the outside and create a network of pinhole leaks that look like tiny wormholes when you cut into the tube. Formicary corrosion tends to be widespread across the coil rather than localized, which usually rules out a simple patch repair.

For a single, localized leak from physical damage, we recover the refrigerant charge, isolate the affected section, and braze a repair directly at the leak point or splice in a short section of new tubing if the damage is more extensive. After the repair we pressure test the entire circuit with dry nitrogen to confirm the fix holds and that there are no other leaks nearby that a first inspection missed, since coil damage from an impact often affects more than the one obviously bent fin. Once the pressure test holds steady, we evacuate the system to remove air and moisture and recharge to the manufacturer's specification.

Repair isn't always the right call. A coil showing multiple leak points, especially the scattered pinhole pattern typical of formicary corrosion, will very likely develop new leaks elsewhere within a season or two even after a successful repair at the current leak site, so we're upfront when replacement is the more sensible long-term choice rather than repeatedly chasing new pinholes. Coil age also factors in: a coil that's ten or more years old and already showing corrosion is a different repair decision than a two-year-old coil damaged by a single hailstorm. Hail is a real consideration in Georgetown, Williamson County sees severe spring storm systems most years, and a hail-damaged coil with bent fins across a wide area but only one active leak point is often still a good repair candidate, since the underlying metal hasn't been chemically compromised the way corrosion-driven leaks have.

Condenser Coil Repair Questions, Georgetown TX

Can any coil leak be repaired instead of replaced? +
No. A single leak from physical damage like a hail strike or debris impact is usually repairable. Widespread pinhole leaks from formicary corrosion typically aren't, since new leaks tend to appear elsewhere on the coil soon after a repair.
How do you know if hail actually caused my coil leak? +
We look for the pattern of damage. Hail typically bends fins across a broad area of the coil face, and the leak point usually correlates with a specific dent or impact mark. Corrosion-driven leaks instead appear as small pitted holes scattered across the tubing without associated fin damage.
What is formicary corrosion? +
It's a slow chemical attack on copper tubing, often linked to certain organic acids from adhesives, cleaning products, or airborne contaminants, that eats microscopic tunnels through the tube wall from the outside. It tends to produce multiple pinhole leaks rather than one clean failure point.
How do you confirm the repair actually holds before recharging? +
After brazing the repair, we pressure test the full circuit with dry nitrogen, typically holding several hundred psi for an extended period, and watch for any pressure drop before we evacuate and recharge with refrigerant.
Will insurance cover a hail-damaged condenser coil? +
That depends on your homeowner's policy and the extent of storm damage to your property overall. We can document the coil damage with photos and a written assessment to support a claim, though we don't handle the insurance claim itself.

AC Not Cooling? Low Refrigerant?