โ„๏ธ HVAC System Evacuation, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Evacuation Standards We Follow on Every Job

System evacuation is the process of removing air, moisture, and other non-condensable gases from a refrigerant circuit using a vacuum pump before charging with refrigerant. It's required any time a system is opened for repair, whether that's a coil replacement, line set repair, compressor swap, or a brand new installation, because atmospheric air and moisture inevitably enter the circuit the moment it's opened, no matter how carefully the work is done. Skipping or rushing evacuation is one of the most common shortcuts that leads to callback problems weeks or months later, since the effects of trapped air and moisture aren't always immediately obvious at startup.

We use calibrated digital micron gauges rather than relying on standard refrigerant gauges, which aren't precise enough at the deep vacuum levels needed to confirm the system is properly evacuated. Our standard target is 500 microns or lower, held steady for a period after isolating the vacuum pump from the system, which confirms both that moisture has fully boiled off and that there's no active leak drawing air back in. We connect through both the high and low side service ports with full-size hoses to reduce flow restriction, since a proper evacuation on a residential system typically needs to move a meaningful volume of air and vapor out through relatively small tubing.

Georgetown's rapid residential growth over the past two decades means we perform evacuation on new system installations just as often as on repairs to older equipment, and new installations actually demand the same rigor, since a brand new coil and line set still need to be purged of the air introduced during shipping, storage, and the installation process itself. We also factor in Central Texas's higher summer humidity when planning evacuation time, since more atmospheric moisture is typically present in the air that enters an open system here than in a drier climate, which can mean needing a longer pump-down or a triple-evacuation approach using nitrogen breaks between vacuum cycles on jobs where moisture contamination is a bigger concern, such as after a compressor burnout. We document the final micron reading and hold time on every job as part of confirming the work meets our standard before recharging.

System Evacuation Questions, Georgetown TX

Is evacuation needed on a brand new AC installation, or just repairs? +
Both. Even a new system has air introduced during manufacturing, shipping, and installation that needs to be removed before charging with refrigerant, so evacuation is a standard step on every new install we perform.
What's the difference between evacuation and just running the vacuum pump for a while? +
Evacuation means verifying the system has reached and held a target micron level, confirming moisture and air are actually gone. Simply running a pump for a fixed time without measuring the result doesn't guarantee the same outcome.
Can a rushed evacuation cause problems later even if the system runs fine at first? +
Yes. Trapped moisture and air can cause gradual issues like acid formation, metering device icing, or reduced efficiency that don't always show up immediately at startup but develop over the following weeks and months.
Why does humidity in Georgetown affect how long evacuation takes? +
Higher ambient humidity means more atmospheric moisture is available to enter the system while it's open, which can require a longer pump-down time or additional nitrogen break cycles to fully remove compared to a drier climate.
How do you verify the evacuation actually worked? +
We use a calibrated digital micron gauge to confirm the system reaches our target vacuum level and holds it steady after isolating the pump, which rules out both remaining moisture and any active leak.