๐Ÿ“ Serving Georgetown, TX & Williamson County Monโ€“Sat 7AMโ€“8PM ยท Sun 9AMโ€“5PM | (512) 798-8094 | โšก Same-Day Service Available
Technicians Available in Georgetown
Same-Day Slots Open
Dispatch: Georgetown TX โ€” not Austin
Average response: 45โ€“90 min
๐ŸงŠ Georgetown TX ยท Same-Day Available

โ„๏ธ Refrigerant Locking Cap Installation โ€” Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment โ€” it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ†4.9โ˜… ยท 312+ Reviews
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
4.9โ˜…
312+ Google Reviews
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging โ€” or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection โ€” effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge โ€” measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge โ€” critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels โ€” we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation โ€” critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores โ€” a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers โ€” required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves โ€” a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils โ€” dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils โ€” including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris โ€” critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils โ€” removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil โ€” low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Frequently Asked Questions โ€” Refrigerant & Coil Services Georgetown

How do I know if my AC needs refrigerant in Georgetown TX? +
Signs of low refrigerant: AC runs constantly but can't cool the house, ice on the suction line, warm air from vents, and higher-than-normal electricity bills. We verify refrigerant charge by measuring subcooling and superheat โ€” not just checking gauge pressure.
How much does AC refrigerant cost in Georgetown TX? +
R-410A: $75โ€“$125/lb installed (most systems hold 3โ€“6 lbs). R-22 (older systems): significantly higher due to phase-out supply constraints. We always inspect for leaks before adding refrigerant โ€” a leaking system will just lose it again.
Is R-22 still available for my older Georgetown AC? +
R-22 production was banned in 2020 but existing stockpiles remain. R-22 recharge costs have risen significantly as supply depletes. If your system uses R-22, we'll give you an honest cost comparison between recharging and replacing the system.
Why does my AC keep losing refrigerant? +
Refrigerant doesn't 'get used up' โ€” it circulates in a closed loop. If you're losing refrigerant, there's a leak. Adding refrigerant without repairing the leak is a short-term fix that becomes increasingly expensive. We find and fix leaks before recharging.

AC Not Cooling? Low Refrigerant?

EPA certified technicians. We find leaks, fix them, then recharge โ€” in that order.