โ„๏ธ Electronic Refrigerant Leak Detection, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

How Electronic Detectors Find Small Leaks

Electronic refrigerant leak detectors work by sensing refrigerant gas molecules in the air immediately around a suspected leak point, using sensor technology, most commonly heated diode or infrared sensors in professional-grade equipment, sensitive enough to detect leak rates as small as a fraction of an ounce per year. That level of sensitivity matters because many real-world refrigerant leaks are slow, a worn Schrader valve, a pinhole from formicary corrosion, or a marginal flare fitting can leak refrigerant gradually over an entire season without producing any visible oil residue or audible hiss, the traditional signs homeowners look for.

Effective electronic leak detection is as much technique as equipment. We move the sensor probe slowly, generally an inch or two per second, along every fitting, joint, valve stem, and coil section in the accessible refrigerant circuit, since moving too quickly lets small leaks pass undetected between passes. We work from the bottom up at each component, since refrigerant is heavier than air and tends to pool near the leak source before dispersing, and outdoor wind or indoor airflow from the system's own blower can carry the gas away from the sensor if we're not working close and methodically. False positives are also a real consideration, ambient refrigerant lingering in a small attic space from a recent repair, or residue from earlier work, can trigger a detector even without an active leak, so we ventilate the area and retest to confirm before pinpointing a repair location.

Attic access is a significant factor in Georgetown, where many homes use single-story ranch layouts with air handlers and line sets routed through attic space that's difficult to move through and often extremely hot during the exact months when refrigerant leaks are most likely to be noticed. We plan our approach to prioritize the most likely leak locations first, brazed joints, service valve stems, and coil connections, based on system age and history, rather than attempting to inspect every inch of line blind. Once a leak is located and confirmed, we mark the exact spot, verify it's the only leak present before assuming the job is done, and then move to repair, whether that's a valve core swap, a braze repair, or a coil-level fix depending on where the leak turned out to be.

Electronic Leak Detection Questions, Georgetown TX

How small a leak can an electronic detector actually find? +
Professional-grade electronic detectors can identify leak rates as small as a fraction of an ounce of refrigerant per year, well below what's needed to produce a visible oil stain or audible hiss, which is why they're the standard for finding slow leaks.
Why does the technician move the sensor so slowly around my system? +
Moving too quickly lets small, low-concentration leaks pass the sensor without being detected. We move deliberately, generally an inch or two per second, along every joint and fitting to make sure nothing gets missed.
Can wind or airflow throw off an electronic leak detector? +
Yes. Outdoor wind at the condenser or airflow from the system's own blower indoors can disperse refrigerant gas before the sensor picks it up, which is why we work close to each component and sometimes need to pause the system's fan during testing.
Why would the detector alarm even when there's no actual leak? +
Residual refrigerant lingering in a small enclosed space like an attic, especially after recent repair work, can trigger a false positive. We ventilate the area and retest to confirm a genuine leak before pinpointing a repair location.
How is electronic detection different from UV dye testing? +
Electronic detection finds refrigerant gas in real time without needing to add anything to the system. UV dye requires injecting dye into the refrigerant and waiting for it to circulate to the leak point, which makes it better suited for intermittent or very slow leaks.