โ„๏ธ Refrigerant Recovery Pumping, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Why Recovery Comes Before Any Repair

Refrigerant recovery is the process of removing refrigerant from a system into a certified recovery cylinder before any work that requires opening the circuit, whether that's a coil replacement, compressor swap, line repair, or brazing work of any kind. It's a legal requirement under EPA Section 608 regulations, which prohibit knowingly venting refrigerant to the atmosphere, and it's also simply good practice, since refrigerant recovered cleanly can sometimes be reused after being checked for contamination, saving cost compared to a full new charge, while venting wastes it entirely and releases a substance with significant global warming potential directly into the air.

We use certified recovery equipment matched to the refrigerant type involved, since R-410A, R-22, and newer lower-GWP refrigerants like R-454B behave differently under recovery conditions and require appropriately rated equipment and recovery cylinders. Recovery speed depends on refrigerant state: liquid recovery from the liquid line is generally faster than vapor recovery from the suction side, so we often use a combination approach, pulling liquid refrigerant first before switching to vapor recovery for whatever remains in the system afterward. We weigh the recovered refrigerant and document the amount, both for our own records and because EPA regulations require tracking refrigerant recovered and its disposition.

Older R-22 systems still in service around Georgetown, a meaningful number of them given how many homes here were built before the 2010 R-22 phase-down began affecting new equipment, require particular care during recovery, since R-22 supply has become increasingly limited and expensive as production has wound down under the phase-out schedule. Recovering R-22 cleanly, without contamination from moisture or oil breakdown, matters more now than it once did if there's any chance the refrigerant can be reused rather than needing replacement with newly reclaimed or virgin supply at today's elevated prices. We check refrigerant condition during recovery and advise homeowners honestly when a system's refrigerant is contaminated enough that reuse isn't realistic, since that affects the overall cost comparison between repairing an aging R-22 system and considering a full replacement to a current refrigerant.

Refrigerant Recovery Questions, Georgetown TX

Is refrigerant recovery legally required, or just a best practice? +
It's legally required under EPA Section 608 regulations, which prohibit venting refrigerant to the atmosphere. Any technician opening a refrigerant circuit for repair must recover the refrigerant into a certified cylinder first.
Can recovered refrigerant be reused? +
Sometimes, if it's not significantly contaminated with moisture, acid, or debris. We check refrigerant condition during recovery and can advise whether reuse is realistic or whether new refrigerant will be needed for recharge.
Why does R-22 recovery get treated differently than R-410A? +
R-22 production has been phased out under federal regulations, making remaining supply increasingly limited and expensive. Recovering it cleanly for potential reuse matters more now given the cost and availability of replacement R-22 compared to more current refrigerants.
How long does refrigerant recovery take? +
It depends on system size and refrigerant state, but a typical residential system usually takes thirty minutes to an hour or so using a combination of liquid and vapor recovery to fully empty the circuit.
What happens to the refrigerant after it's recovered? +
It's either reused after verification of its condition, sent for reclamation and reprocessing if contaminated but recoverable, or properly disposed of through licensed channels if it can't be reused, all in compliance with EPA requirements.