Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Routine Coil Care and Why It Matters

The condenser coil is the outdoor half of your refrigerant circuit, responsible for rejecting the heat your indoor coil absorbed from the house. It works by pushing outdoor air across finned copper tubing carrying hot, high-pressure refrigerant gas, condensing it back into a liquid before it heads to the metering device. That heat rejection only works efficiently when air can move freely through the fins. Even a thin, even layer of dirt across the coil face measurably raises head pressure and discharge temperature, forcing the compressor to work harder to move the same amount of heat, which shows up as reduced cooling capacity and higher electricity use long before the system fails outright.

Georgetown's spring season brings heavy oak and cottonwood debris, along with general dust from ongoing residential construction throughout Williamson County subdivisions, and all of it settles on outdoor coils positioned at ground level near landscaping. Grass clippings from mowing close to the unit are another frequent contributor we see on service calls. Left unaddressed for a full season or more, that buildup compacts against the fins and becomes much harder to remove with a simple rinse, which is part of why we recommend coil cleaning as a standing item during routine seasonal maintenance rather than only after cooling performance has already noticeably dropped.

Our service process starts with a visual inspection of fin condition, checking for bent fins that restrict airflow independent of dirt buildup, along with an inspection of the coil for any early signs of corrosion or oil residue that would indicate a developing leak. We then clean the coil with a coil-safe cleaner and low-pressure rinse, working from the inside of the coil outward relative to normal airflow direction so debris is flushed out rather than pushed further into the fin pack. For fins that have been bent from debris impact or contact during landscaping work, we use a fin comb to straighten them back into alignment, restoring the airflow path between fins. After cleaning, we check operating pressures and subcooling to confirm the coil is transferring heat correctly, since a clean coil with unresolved airflow restriction elsewhere or bent fins can still underperform even after service.

Condenser Coil Service Questions, Georgetown TX

How often should my condenser coil be cleaned? +
We generally recommend coil cleaning once a year as part of seasonal maintenance, ideally before the heavy summer cooling season begins, though homes with more landscaping debris, pet hair, or nearby construction dust may benefit from more frequent attention.
Can I clean the condenser coil myself with a garden hose? +
Light rinsing from outside the unit can help between professional services, but a hose alone won't remove compacted debris or reach the coil fins from the correct direction. We use coil-safe cleaners and rinse from the inside out for a more thorough result.
Does a dirty coil actually raise my electric bill? +
Yes. Restricted airflow across a dirty coil forces the compressor to run at higher head pressure to reject the same amount of heat, which increases power draw and can meaningfully raise summer electricity costs even before the system shows other symptoms.
What causes bent fins on my condenser coil? +
Common causes include debris impact from mowing or storms, contact during landscaping or pressure washing nearby, and simple age. We straighten bent fins with a fin comb during service when it's affecting airflow.
Is coil cleaning included in a regular maintenance visit? +
It's typically part of a full maintenance service, but the depth of cleaning can vary. If your coil has heavier buildup, we'll flag whether a more thorough cleaning or acid wash is warranted beyond standard service.