๐Ÿ“ Serving Georgetown, TX & Williamson County Mon-Sat 7AM-8PM ยท Sun 9AM-5PM | (512) 798-8094 | โšก Same-Day Service Available
Technicians Available in Georgetown
Same-Day Slots Open
Dispatch: Georgetown TX, not Austin
Average response: 45-90 min
๐ŸงŠ Georgetown TX ยท Same-Day Available

โ„๏ธ Refrigerant Retrofit Conversions, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Converting an Older System to a Different Refrigerant

A refrigerant retrofit means converting a system originally designed for one refrigerant, most commonly R-22 on older equipment, to run on a different, currently available refrigerant, since R-22 production has been phased out under federal regulation and remaining supply is limited and increasingly expensive. Retrofit isn't as simple as draining out the old refrigerant and charging in something new, because different refrigerants have different pressure-temperature relationships, different oil compatibility requirements, and different volumetric efficiency, meaning a straight refrigerant swap without other changes often produces a system that runs but performs poorly or puts unusual stress on the compressor.

The most common approach for R-22 systems is converting to one of the approved drop-in replacement refrigerants formulated to closely match R-22's operating characteristics while being compatible, or nearly compatible, with the existing mineral oil already in the system, avoiding a full oil change in some cases. This requires recovering the existing R-22, flushing if oil compatibility is a concern, replacing the filter drier, and recharging with the replacement refrigerant at a different weight than the original R-22 charge, since these substitutes typically require a different charge amount to achieve equivalent performance, verified by measuring subcooling and superheat against the replacement refrigerant's specific pressure-temperature chart rather than the R-22 chart the system was originally designed around.

We're honest with Georgetown homeowners that a retrofit is often a bridge solution rather than a permanent one, particularly on a system that's already older and near the end of its expected service life for other reasons, condenser or evaporator coil age, compressor wear, or general system efficiency compared to current equipment. A retrofit can be the right call when a home's system otherwise has significant remaining life and a single refrigerant leak has simply made recharging with increasingly scarce R-22 impractical, but for a system with multiple age-related concerns, we walk through the full cost comparison between retrofit and replacement so the decision reflects the system's real condition, not just the immediate refrigerant availability problem. Georgetown has a substantial number of homes built before 2010 still running original R-22 equipment, making this a conversation we have regularly.

Refrigerant Retrofit Questions, Georgetown TX

Can any R-22 system be converted to a different refrigerant? +
Most can be retrofitted, but compatibility depends on the specific compressor, metering device, and overall system condition. We evaluate the equipment before recommending a retrofit rather than assuming every system is a good candidate.
Will a retrofit make my system perform exactly like it did on R-22? +
It should perform close to original capacity if done correctly with proper charge weight and verification, but replacement refrigerants aren't a perfect one-to-one match for R-22's characteristics, so some difference in performance can occur.
Is retrofitting cheaper than replacing my whole system? +
Usually, in the short term, but it's not always the better long-term value if the system has other age-related issues. We walk through the full comparison so you can weigh upfront retrofit cost against the remaining useful life of the equipment.
Why is R-22 refrigerant so expensive now? +
R-22 production was phased out under federal environmental regulation, and remaining supply comes only from stockpiles and reclaimed refrigerant, which has driven prices up significantly compared to when the refrigerant was still being manufactured.
Does a retrofit require replacing the compressor? +
Not usually, provided the existing compressor is compatible with the replacement refrigerant and its oil, which is common for approved R-22 drop-in replacements. We check compressor condition and compatibility before proceeding.

AC Not Cooling? Low Refrigerant?

EPA certified technicians. We find leaks, fix them, then recharge, in that order.

๐Ÿ“ž Call Now
(512) 798-8094