โ„๏ธ Evaporator Coil Service, Georgetown TX

Refrigerant work requires EPA Section 608 certification and proper equipment, it's not a DIY repair. ProAir Georgetown's technicians are EPA certified, carry electronic and UV leak detection equipment, and stock the refrigerant types common in Georgetown homes. We find and fix leaks correctly, not just recharge and send you on your way.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

Important: Refrigerant work is EPA regulated. ProAir Georgetown technicians hold current EPA Section 608 Universal certification. We recover, recycle, and recharge refrigerant according to federal regulations and never vent refrigerants to atmosphere.

Refrigerant Leak Detection & Testing

๐Ÿ”
Refrigerant Leak Detection

Professional leak detection using electronic sniffers and UV dye. Find leaks before recharging, or recharge just moves the problem.

๐Ÿ“ก
Electronic Refrigerant Leak Detection

High-sensitivity electronic leak detectors locate small leaks in coils, line sets, and fittings that visual inspection misses.

๐ŸŸก
UV Dye Refrigerant Leak Testing

UV dye injection and black light inspection, effective for finding intermittent or slow leaks that evade electronic detection.

๐Ÿ”ฌ
Nitrogen Pressure Testing

Pressure test refrigerant circuits with dry nitrogen to verify leak-free condition before charging new refrigerant.

Refrigerant Service & Recovery

โ„๏ธ
Refrigerant Recharge

Proper refrigerant recharge, measured by subcooling and superheat, not just pressure gauges. We charge to manufacturer spec.

โ™ป๏ธ
Refrigerant Recovery & Pumping

EPA-compliant refrigerant recovery before any system work requiring circuit opening.

๐Ÿญ
HVAC System Evacuation

Deep vacuum pull to remove moisture and non-condensables before refrigerant charge, critical for system longevity.

๐Ÿ’จ
Deep Vacuum AC Lines

Extended deep vacuum to achieve proper micron levels, we don't rush this step that protects compressor life.

๐Ÿ”„
Refrigerant Retrofit Conversions

Convert systems from discontinued refrigerants to approved drop-in or replacement refrigerants.

Line Set Service & Repair

๐Ÿ”ง
Copper Line Set Flushing

Flush contaminated line sets during compressor replacement to prevent new compressor failure from acid or debris.

๐Ÿ”ฅ
Copper Line Leak Brazing

Professional braze repair of pinhole leaks and joint failures in copper refrigerant lines.

๐Ÿ”Œ
Liquid Line Pipe Repair

Repair damaged liquid line sections including crimps, kinks, and corrosion failures.

๐Ÿงฅ
Suction Line Insulation Replacement

Replace deteriorated suction line insulation, critical for efficiency and preventing condensation in Georgetown's humid summers.

๐Ÿ”’
Line Set Wall Penetration Sealing

Seal wall and foundation penetrations around line sets to prevent pest entry and air infiltration.

๐Ÿ”’
Refrigerant Locking Cap Installation

Install locking valve caps to prevent refrigerant theft and unauthorized access to Schrader valves.

Cooling Circuit Components

๐Ÿ”Œ
AC Schrader Valve Leak Repair

Replace leaking Schrader valve cores, a small but common source of refrigerant loss over time.

๐Ÿ”ต
Liquid Line Filter Drier Installation

Install or replace liquid line filter driers, required after any system opening to remove moisture and acid.

๐Ÿ”ง
AC Service Valve Replacement

Replace leaking or damaged service valves on compressors and line set connections.

๐Ÿ”„
AC Accumulator Replacement

Replace failed accumulators that protect compressors from liquid refrigerant slugging.

๐ŸŽ›๏ธ
TXV Replacement

Replace failed thermostatic expansion valves, a hunting or stuck TXV causes refrigerant distribution problems and efficiency loss.

๐Ÿ”ง
AC Muffler Repair

Repair or replace discharge line mufflers that reduce compressor noise and vibration.

Evaporator & Condenser Coil Service

โ„๏ธ
Evaporator Coil Service

Clean, inspect, and service evaporator coils, dirty coils are a leading cause of reduced cooling capacity in Georgetown homes.

๐Ÿ”„
Evaporator Coil Replacement

Replace failed or leaking evaporator coils, including proper refrigerant recovery, installation, and recharge.

๐Ÿ“
Evaporator Coil Fin Straightening

Straighten bent evaporator fins to restore full airflow through the coil and recover lost capacity.

โ˜€๏ธ
Condenser Coil Service

Clean condenser coils fouled by Georgetown's cottonwood, dust, and debris, critical for summer efficiency.

๐Ÿ”ง
Condenser Coil Repair

Repair pinhole leaks and minor damage in condenser coils when full replacement isn't required.

๐Ÿงด
Condenser Coil Acid Wash

Deep acid wash for severely fouled condenser coils, removes mineral scale, oxidation, and embedded debris.

โ„๏ธ
Frozen Evaporator Coil Repair

Address the root cause of a frozen evaporator coil, low refrigerant or restricted airflow. We fix the cause, not just defrost.

๐ŸงŠ
AC Copper Pipe Ice Repair

Diagnose and repair the refrigerant or airflow condition causing ice formation on copper suction lines.

Keeping Your Evaporator Coil Clean

The evaporator coil is where the cooling actually happens inside your home, absorbing heat from the air that flows across it before that air is pushed through your ductwork. Because it operates cold and wet, condensation forms on its surface during nearly every cooling cycle, and that moist environment is ideal for dust, pet dander, and airborne particles to stick and accumulate on the fin surface over time. A layer of buildup on the coil acts as insulation, reducing how effectively the coil can transfer heat from the passing air, and it also restricts airflow the same way dirt does on a filter, both effects working together to reduce cooling capacity and system efficiency.

Georgetown's cedar fever season each winter, when juniper pollen blankets the area, along with a long allergy season overall from oak and grass pollens common to Central Texas, means homes here often pull more airborne particulate through their return air system than homes in regions with shorter or milder pollen seasons. Combined with normal household dust and pet hair, that adds up to coil buildup that develops faster than many homeowners expect, particularly if air filters aren't changed on a regular schedule, since a coil is essentially a secondary filter catching whatever gets past the primary one.

Service involves inspecting the coil visually with a mirror and flashlight or by pulling an access panel, checking both fin condition and buildup level, then cleaning with a coil-safe foaming or no-rinse cleaner formulated for evaporator coils specifically, since some cleaners designed for outdoor condenser coils aren't appropriate for the tighter, less-ventilated space of an evaporator cabinet. We also check the condensate drain pan and drain line during coil service, since a coil producing normal condensation needs that water to actually leave the system, and a clogged drain combined with coil buildup compounds moisture problems in the cabinet. After cleaning, we verify airflow has improved and check operating temperatures and pressures to confirm the coil is performing correctly, since a visibly cleaner coil doesn't always mean full performance has been restored if there's also a fin damage or airflow issue elsewhere in the system.

Evaporator Coil Service Questions, Georgetown TX

How can I tell if my evaporator coil needs cleaning? +
Reduced airflow from your vents, a musty smell when the system runs, ice forming on the coil or lines, and rising energy bills without another clear cause are all signs worth having the coil inspected.
Does cedar fever season really affect my AC coil? +
Yes. The heavy juniper pollen that blankets Central Texas each winter, along with oak and grass pollen through spring, gets pulled into return air systems and can accumulate on the evaporator coil faster than in regions with a shorter allergy season.
Can I clean the evaporator coil myself? +
Accessing the coil safely usually requires removing air handler panels and sometimes disconnecting ductwork, and using the wrong cleaner or too much water can damage electrical components nearby, so we generally recommend professional service for this.
Is evaporator coil cleaning part of a standard maintenance visit? +
A visual inspection typically is, but a full cleaning is usually recommended as a separate service when buildup is found, since it takes more time and different products than a quick inspection.
What happens if I never clean the evaporator coil? +
Over years, enough buildup accumulates to noticeably reduce cooling capacity and can contribute to icing, reduced airflow, and higher energy costs, eventually shortening the life of the coil and other system components working harder to compensate.

AC Not Cooling? Low Refrigerant?

EPA certified technicians. We find leaks, fix them, then recharge, in that order.