Most HVAC failures come down to a specific component, a capacitor burned out by Georgetown's heat, a contractor pitted from cycling, a blower motor bearing that's been failing for months. ProAir Georgetown carries the most common replacement components on every service truck so we can complete repairs same-day instead of ordering parts and scheduling a return visit.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

HVAC Components We Repair & Replace, Georgetown TX

Motors & Fans

๐Ÿ”ง
Blower Motor Repair

Diagnose and repair indoor blower motor failures, bearing wear, winding failure, and capacitor issues.

๐Ÿ”„
AC Blower Motor Replacement

Replace failed indoor blower motors, we stock common motors for Carrier, Trane, Lennox, Goodman, and Rheem.

๐Ÿ’ง
Blower Motor Bearing Lubrication

Lubricate blower motor bearings before they fail, catches motors that squeal before they burn out.

๐Ÿงน
Furnace Blower Wheel Cleaning

Clean blower wheels coated with dust and debris that reduce airflow and strain the motor.

๐Ÿ”ง
Fan Motor Repair

Repair or replace condenser fan motors, outdoor fan failure causes compressor overheating on Georgetown's 100ยฐF days.

โšก
Condenser Fan Motor Repair

Diagnose and repair outdoor condenser fan motor failures, common cause of AC shutdown in peak summer heat.

๐Ÿ”„
Outdoor Fan Blade Replacement

Replace cracked, bent, or imbalanced outdoor fan blades causing vibration and motor strain.

Capacitors & Contactors

โšก
Capacitor Replacement

The #1 Georgetown summer repair. Capacitors overheat and fail in sustained 100ยฐF+ heat, fast, affordable fix.

๐Ÿ”
AC Capacitor Testing & Replacement

Test capacitors before replacing, an out-of-spec capacitor causes the same symptoms as a failed compressor.

โšก
Run Capacitor Replacement

Replace failed run capacitors on compressors and fan motors, the most common summer AC component failure.

โšก
Start Capacitor Replacement

Replace start capacitors that provide the extra torque needed to start compressors on hot days.

๐Ÿ”‹
Hard Start Kit Installation

Install hard start kits on aging compressors to reduce starting current and extend compressor life.

๐Ÿ”Œ
Contactor Replacement

Replace pitted or failed contactors, the relay that connects power to the compressor and condenser fan.

๐Ÿ”Œ
AC Contactor Replacement

Replace AC contactors with pitted contacts that cause intermittent power to compressor and outdoor fan.

Compressor Service

๐Ÿ”ง
Compressor Repair

Diagnose compressor failures, not every compressor problem requires replacement. We test before recommending replacement.

๐Ÿ”„
AC Compressor Replacement

Compressor replacement with full circuit flush, filter drier, evacuation, and recharge, done correctly to protect the new compressor.

๐Ÿ”‡
AC Muffler Repair

Replace discharge mufflers that reduce compressor noise and protect the refrigerant circuit.

๐Ÿ”ฅ
Compressor Crankcase Heater Installation

Install crankcase heaters to prevent refrigerant migration into compressor oil during cold Texas nights.

โฌ†๏ธ
High Pressure Switch Replacement

Replace failed high-pressure safety switches that protect compressors from dangerously high discharge pressure.

โฌ‡๏ธ
Low Pressure Switch Replacement

Replace low-pressure safety switches that prevent compressor damage from loss of refrigerant charge.

Furnace Components

โฌ†๏ธ
High Limit Switch Replacement

Replace failed high-limit switches that shut furnaces down on overheating, essential safety component.

๐Ÿ–ฅ๏ธ
Furnace Control Board Replacement

Replace faulty furnace control boards, we test all connected components first to confirm the board is the failure.

๐Ÿ”ง
Furnace Fan Control Switch Repair

Repair or replace fan control switches that govern blower timing in older furnaces without electronic control boards.

๐Ÿ”ฅ
Furnace Hot Surface Ignitor Replacement

Replace fragile silicon carbide or silicon nitride ignitors, the #1 furnace no-heat repair in Georgetown.

๐Ÿ”ฅ
Furnace Flame Sensor Replacement

Replace or clean flame sensors that fail to detect the burner flame, causing furnace lockout.

๐Ÿ”ง
Furnace Gas Valve Replacement

Replace failed gas valves that prevent gas flow to burners, verified diagnosis before replacement.

๐ŸŒก๏ธ
Furnace Thermocouple Replacement

Replace thermocouples on older standing pilot furnaces that fail to keep the pilot lit.

๐Ÿ”’
Furnace Rollout Switch Replacement

Replace tripped rollout switches, but also diagnose why flames rolled out, as this indicates a serious underlying condition.

๐Ÿ’จ
Draft Inducer Motor Replacement

Replace failed draft inducer motors in 80%+ efficiency furnaces, failure causes pressure switch trips and no-heat conditions.

โšก
Electric Furnace Heating Element Replacement

Replace failed heating elements in electric furnaces, test all elements and sequencers before partial replacement.

โšก
Electric Heating Sequencer Replacement

Replace failed sequencers that stagger heating element startup to prevent circuit overload.

๐Ÿ”ฅ
Pilot Tubing Replacement

Replace cracked or blocked pilot tubing on older standing pilot furnaces and boilers.

๐Ÿ”ฅ
Standing Pilot Light Repair

Repair standing pilot assembly issues on older furnaces, thermocouple, pilot orifice, and gas valve.

๐Ÿ”ง
Main Gas Shutoff Valve Replacement

Replace corroded or leaking main gas shutoff valves at HVAC equipment.

Outdoor Unit & Noise Components

๐Ÿ”‡
Outdoor Unit Sound Blanket Installation

Install compressor sound blankets to reduce outdoor unit noise, particularly useful in Georgetown's zero-lot-line neighborhoods.

๐Ÿ”‡
AC Vibration Isolation Pad Replacement

Replace deteriorated equipment pads and isolation mounts that transmit vibration through slabs and walls.

How We Test a Capacitor Before Replacing It

A dual run capacitor is the small metal can mounted near your outdoor condenser that stores an electrical charge and feeds it to both the compressor motor and the condenser fan motor at the same time, using separate terminals labeled Herm, Fan, and Common. Its job is to keep the start winding of each motor energized while the motor is running, which is what lets a single phase motor keep spinning smoothly instead of stalling.

Rather than replace a capacitor on sight, we test it with a capacitance meter and compare the reading against the microfarad rating printed on the can. Manufacturers allow a tolerance, usually plus or minus 6 percent, and a capacitor reading outside that range is failing even if the unit still limps along. We also visually inspect the top of the can for bulging, which happens as internal gas pressure builds from a breaking down dielectric film, a bulged or leaking capacitor is replaced regardless of what the meter shows since physical failure is imminent.

Testing before replacing matters because a weak capacitor produces symptoms that look identical to a failing compressor or fan motor: humming without starting, slow or hesitant startup, or a breaker trip on start attempt. Swapping in a new capacitor and confirming normal amp draw on both motors afterward tells us definitively whether the capacitor was the actual problem or whether there is a deeper motor or contactor issue underneath it.

Georgetown's sustained summer heat is the single biggest driver of capacitor failure in this area. The electrolytic film inside the capacitor degrades chemically at a rate that roughly doubles for every 18 degree rise in operating temperature, and outdoor units baking in direct sun on 100 plus degree days routinely see internal capacitor temperatures well above what the same equipment would see in a milder climate. That's why capacitor failure is the most common single AC repair call we run between May and September.

When we replace a capacitor, we match the microfarad rating and voltage rating exactly rather than substituting a close value, and we verify the new capacitor's terminal wiring matches the old one before restoring power, a miswired dual capacitor can damage the compressor or fan motor on the very first start cycle.

Frequently Asked Questions, AC Capacitor Testing & Replacement

What microfarad tolerance do you use when testing a capacitor? +
We follow manufacturer tolerance, typically plus or minus 6 percent of the rated microfarad value stamped on the capacitor. A reading outside that range means the capacitor is failing and should be replaced even if the system is still running.
Can a bulging capacitor still test within range? +
It can briefly, but a bulged top means the internal dielectric film is already breaking down and building gas pressure. We replace any capacitor showing physical bulging or leakage regardless of what the meter reads, since failure is imminent.
Do you use a dual capacitor or two separate capacitors on replacement? +
We replace like for like whenever the original equipment used a dual run capacitor for the compressor and fan motor. If your system uses separate single capacitors we replace them the same way, matching each one's individual rating.
What happens if a dual capacitor is wired backward during replacement? +
Miswiring the Herm, Fan, and Common terminals can send the wrong starting charge to a motor and cause immediate damage on the next start cycle. We always verify terminal wiring against the original before restoring power.
Why does my capacitor keep failing every year or two? +
Repeated early failure usually points to a secondary cause, sustained high head pressure from a dirty condenser coil, a weak run capacitor being asked to compensate for a tired compressor, or an undersized capacitor for the equipment. We check for those root causes rather than just swapping the part again.