Most HVAC failures come down to a specific component, a capacitor burned out by Georgetown's heat, a contractor pitted from cycling, a blower motor bearing that's been failing for months. ProAir Georgetown carries the most common replacement components on every service truck so we can complete repairs same-day instead of ordering parts and scheduling a return visit.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

HVAC Components We Repair & Replace, Georgetown TX

Motors & Fans

๐Ÿ”ง
Blower Motor Repair

Diagnose and repair indoor blower motor failures, bearing wear, winding failure, and capacitor issues.

๐Ÿ”„
AC Blower Motor Replacement

Replace failed indoor blower motors, we stock common motors for Carrier, Trane, Lennox, Goodman, and Rheem.

๐Ÿ’ง
Blower Motor Bearing Lubrication

Lubricate blower motor bearings before they fail, catches motors that squeal before they burn out.

๐Ÿงน
Furnace Blower Wheel Cleaning

Clean blower wheels coated with dust and debris that reduce airflow and strain the motor.

๐Ÿ”ง
Fan Motor Repair

Repair or replace condenser fan motors, outdoor fan failure causes compressor overheating on Georgetown's 100ยฐF days.

โšก
Condenser Fan Motor Repair

Diagnose and repair outdoor condenser fan motor failures, common cause of AC shutdown in peak summer heat.

๐Ÿ”„
Outdoor Fan Blade Replacement

Replace cracked, bent, or imbalanced outdoor fan blades causing vibration and motor strain.

Capacitors & Contactors

โšก
Capacitor Replacement

The #1 Georgetown summer repair. Capacitors overheat and fail in sustained 100ยฐF+ heat, fast, affordable fix.

๐Ÿ”
AC Capacitor Testing & Replacement

Test capacitors before replacing, an out-of-spec capacitor causes the same symptoms as a failed compressor.

โšก
Run Capacitor Replacement

Replace failed run capacitors on compressors and fan motors, the most common summer AC component failure.

โšก
Start Capacitor Replacement

Replace start capacitors that provide the extra torque needed to start compressors on hot days.

๐Ÿ”‹
Hard Start Kit Installation

Install hard start kits on aging compressors to reduce starting current and extend compressor life.

๐Ÿ”Œ
Contactor Replacement

Replace pitted or failed contactors, the relay that connects power to the compressor and condenser fan.

๐Ÿ”Œ
AC Contactor Replacement

Replace AC contactors with pitted contacts that cause intermittent power to compressor and outdoor fan.

Compressor Service

๐Ÿ”ง
Compressor Repair

Diagnose compressor failures, not every compressor problem requires replacement. We test before recommending replacement.

๐Ÿ”„
AC Compressor Replacement

Compressor replacement with full circuit flush, filter drier, evacuation, and recharge, done correctly to protect the new compressor.

๐Ÿ”‡
AC Muffler Repair

Replace discharge mufflers that reduce compressor noise and protect the refrigerant circuit.

๐Ÿ”ฅ
Compressor Crankcase Heater Installation

Install crankcase heaters to prevent refrigerant migration into compressor oil during cold Texas nights.

โฌ†๏ธ
High Pressure Switch Replacement

Replace failed high-pressure safety switches that protect compressors from dangerously high discharge pressure.

โฌ‡๏ธ
Low Pressure Switch Replacement

Replace low-pressure safety switches that prevent compressor damage from loss of refrigerant charge.

Furnace Components

โฌ†๏ธ
High Limit Switch Replacement

Replace failed high-limit switches that shut furnaces down on overheating, essential safety component.

๐Ÿ–ฅ๏ธ
Furnace Control Board Replacement

Replace faulty furnace control boards, we test all connected components first to confirm the board is the failure.

๐Ÿ”ง
Furnace Fan Control Switch Repair

Repair or replace fan control switches that govern blower timing in older furnaces without electronic control boards.

๐Ÿ”ฅ
Furnace Hot Surface Ignitor Replacement

Replace fragile silicon carbide or silicon nitride ignitors, the #1 furnace no-heat repair in Georgetown.

๐Ÿ”ฅ
Furnace Flame Sensor Replacement

Replace or clean flame sensors that fail to detect the burner flame, causing furnace lockout.

๐Ÿ”ง
Furnace Gas Valve Replacement

Replace failed gas valves that prevent gas flow to burners, verified diagnosis before replacement.

๐ŸŒก๏ธ
Furnace Thermocouple Replacement

Replace thermocouples on older standing pilot furnaces that fail to keep the pilot lit.

๐Ÿ”’
Furnace Rollout Switch Replacement

Replace tripped rollout switches, but also diagnose why flames rolled out, as this indicates a serious underlying condition.

๐Ÿ’จ
Draft Inducer Motor Replacement

Replace failed draft inducer motors in 80%+ efficiency furnaces, failure causes pressure switch trips and no-heat conditions.

โšก
Electric Furnace Heating Element Replacement

Replace failed heating elements in electric furnaces, test all elements and sequencers before partial replacement.

โšก
Electric Heating Sequencer Replacement

Replace failed sequencers that stagger heating element startup to prevent circuit overload.

๐Ÿ”ฅ
Pilot Tubing Replacement

Replace cracked or blocked pilot tubing on older standing pilot furnaces and boilers.

๐Ÿ”ฅ
Standing Pilot Light Repair

Repair standing pilot assembly issues on older furnaces, thermocouple, pilot orifice, and gas valve.

๐Ÿ”ง
Main Gas Shutoff Valve Replacement

Replace corroded or leaking main gas shutoff valves at HVAC equipment.

Outdoor Unit & Noise Components

๐Ÿ”‡
Outdoor Unit Sound Blanket Installation

Install compressor sound blankets to reduce outdoor unit noise, particularly useful in Georgetown's zero-lot-line neighborhoods.

๐Ÿ”‡
AC Vibration Isolation Pad Replacement

Replace deteriorated equipment pads and isolation mounts that transmit vibration through slabs and walls.

A Safety Switch That Should Never Just Be Reset

The flame rollout switch is a manual-reset high-temperature safety switch mounted near the burner compartment, positioned specifically to detect the heat of a flame that has rolled outward, away from its intended path into the heat exchanger, rather than staying contained where it should burn. Under normal operation, burner flames travel up into the heat exchanger tubes and never come close to where the rollout switch is mounted, so a tripped rollout switch is always telling you something has gone genuinely wrong with combustion, not that the switch itself is randomly malfunctioning.

Flame rollout has a handful of underlying causes, and diagnosing the actual cause is more important than the switch replacement itself. A blocked or significantly restricted heat exchanger, often from years of accumulated debris or corrosion, forces combustion gases and flame to find an alternate path outward rather than through their intended route. A cracked heat exchanger can similarly redirect flame and combustion gases. A failing or undersized draft inducer that isn't pulling flue gases through properly at an adequate rate can also cause flames to roll outward from the burner rather than being drawn correctly into the heat exchanger passages.

Because a manual-reset rollout switch requires physically pressing a reset button to restore operation after it trips, and because it's a safety device specifically protecting against a fire and carbon monoxide hazard, we treat any tripped rollout switch as a full diagnostic event, never a quick reset-and-move-on repair. We inspect the heat exchanger condition, verify draft inducer performance and pressure switch operation, and check burner alignment and flame pattern before ever simply resetting the switch and calling the furnace fixed, resetting it without addressing the root cause just sets up the same dangerous condition to recur.

If the rollout switch itself has failed, meaning it's not tripping when it should, or has become unreliable in resetting properly, we replace it matching the exact temperature rating and mounting configuration to the original. But the switch replacement is almost always the smaller part of this service call, the real work is confirming why flame rolled out in the first place and making sure that underlying cause is fully resolved.

Frequently Asked Questions, Furnace Rollout Switch Replacement

Is it safe to just reset a tripped rollout switch myself? +
We strongly advise against it. A tripped rollout switch indicates flame escaped its intended path, which points to a genuine combustion problem, a blocked or cracked heat exchanger, or an inducer issue, that needs to be diagnosed and fixed, not just reset and ignored.
What actually causes flame rollout in the first place? +
Common causes include a heat exchanger blocked by accumulated debris or corrosion, a cracked heat exchanger redirecting combustion gases, or a draft inducer that isn't generating adequate draft to pull flue gases through their intended path. We investigate all three before considering the repair complete.
Do you always replace the switch when it trips, or sometimes just reset it after diagnosis? +
If the switch itself is functioning correctly, meaning it tripped appropriately in response to a real heat event, we replace it only if it's failing to reset properly or its temperature rating has drifted. Most of our work on a rollout trip focuses on the root combustion cause rather than the switch.
Can a cracked heat exchanger really cause this? +
Yes, a crack can redirect combustion gases and flame outside their intended path through the heat exchanger tubes, both tripping a rollout switch and creating a genuine carbon monoxide risk if the crack also allows exhaust gases to mix into supply air. We inspect the exchanger carefully whenever rollout has occurred.
How urgent is a rollout switch trip? +
Very. We treat this as a priority safety diagnostic rather than routine scheduling, since it indicates an active combustion problem that shouldn't be worked around by repeated manual resets.