๐Ÿ“ Serving Georgetown, TX & Williamson County Mon-Sat 7AM-8PM ยท Sun 9AM-5PM | (512) 798-8094 | โšก Same-Day Service Available
Technicians Available in Georgetown
Same-Day Slots Open
Dispatch: Georgetown TX, not Austin
Average response: 45-90 min
๐Ÿ”ฉ Georgetown TX ยท Same-Day Available

๐Ÿ”ง Hard Start Kit Installation, Georgetown TX

Most HVAC failures come down to a specific component, a capacitor burned out by Georgetown's heat, a contractor pitted from cycling, a blower motor bearing that's been failing for months. ProAir Georgetown carries the most common replacement components on every service truck so we can complete repairs same-day instead of ordering parts and scheduling a return visit.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

HVAC Components We Repair & Replace, Georgetown TX

Motors & Fans

๐Ÿ”ง
Blower Motor Repair

Diagnose and repair indoor blower motor failures, bearing wear, winding failure, and capacitor issues.

๐Ÿ”„
AC Blower Motor Replacement

Replace failed indoor blower motors, we stock common motors for Carrier, Trane, Lennox, Goodman, and Rheem.

๐Ÿ’ง
Blower Motor Bearing Lubrication

Lubricate blower motor bearings before they fail, catches motors that squeal before they burn out.

๐Ÿงน
Furnace Blower Wheel Cleaning

Clean blower wheels coated with dust and debris that reduce airflow and strain the motor.

๐Ÿ”ง
Fan Motor Repair

Repair or replace condenser fan motors, outdoor fan failure causes compressor overheating on Georgetown's 100ยฐF days.

โšก
Condenser Fan Motor Repair

Diagnose and repair outdoor condenser fan motor failures, common cause of AC shutdown in peak summer heat.

๐Ÿ”„
Outdoor Fan Blade Replacement

Replace cracked, bent, or imbalanced outdoor fan blades causing vibration and motor strain.

Capacitors & Contactors

โšก
Capacitor Replacement

The #1 Georgetown summer repair. Capacitors overheat and fail in sustained 100ยฐF+ heat, fast, affordable fix.

๐Ÿ”
AC Capacitor Testing & Replacement

Test capacitors before replacing, an out-of-spec capacitor causes the same symptoms as a failed compressor.

โšก
Run Capacitor Replacement

Replace failed run capacitors on compressors and fan motors, the most common summer AC component failure.

โšก
Start Capacitor Replacement

Replace start capacitors that provide the extra torque needed to start compressors on hot days.

๐Ÿ”‹
Hard Start Kit Installation

Install hard start kits on aging compressors to reduce starting current and extend compressor life.

๐Ÿ”Œ
Contactor Replacement

Replace pitted or failed contactors, the relay that connects power to the compressor and condenser fan.

๐Ÿ”Œ
AC Contactor Replacement

Replace AC contactors with pitted contacts that cause intermittent power to compressor and outdoor fan.

Compressor Service

๐Ÿ”ง
Compressor Repair

Diagnose compressor failures, not every compressor problem requires replacement. We test before recommending replacement.

๐Ÿ”„
AC Compressor Replacement

Compressor replacement with full circuit flush, filter drier, evacuation, and recharge, done correctly to protect the new compressor.

๐Ÿ”‡
AC Muffler Repair

Replace discharge mufflers that reduce compressor noise and protect the refrigerant circuit.

๐Ÿ”ฅ
Compressor Crankcase Heater Installation

Install crankcase heaters to prevent refrigerant migration into compressor oil during cold Texas nights.

โฌ†๏ธ
High Pressure Switch Replacement

Replace failed high-pressure safety switches that protect compressors from dangerously high discharge pressure.

โฌ‡๏ธ
Low Pressure Switch Replacement

Replace low-pressure safety switches that prevent compressor damage from loss of refrigerant charge.

Furnace Components

โฌ†๏ธ
High Limit Switch Replacement

Replace failed high-limit switches that shut furnaces down on overheating, essential safety component.

๐Ÿ–ฅ๏ธ
Furnace Control Board Replacement

Replace faulty furnace control boards, we test all connected components first to confirm the board is the failure.

๐Ÿ”ง
Furnace Fan Control Switch Repair

Repair or replace fan control switches that govern blower timing in older furnaces without electronic control boards.

๐Ÿ”ฅ
Furnace Hot Surface Ignitor Replacement

Replace fragile silicon carbide or silicon nitride ignitors, the #1 furnace no-heat repair in Georgetown.

๐Ÿ”ฅ
Furnace Flame Sensor Replacement

Replace or clean flame sensors that fail to detect the burner flame, causing furnace lockout.

๐Ÿ”ง
Furnace Gas Valve Replacement

Replace failed gas valves that prevent gas flow to burners, verified diagnosis before replacement.

๐ŸŒก๏ธ
Furnace Thermocouple Replacement

Replace thermocouples on older standing pilot furnaces that fail to keep the pilot lit.

๐Ÿ”’
Furnace Rollout Switch Replacement

Replace tripped rollout switches, but also diagnose why flames rolled out, as this indicates a serious underlying condition.

๐Ÿ’จ
Draft Inducer Motor Replacement

Replace failed draft inducer motors in 80%+ efficiency furnaces, failure causes pressure switch trips and no-heat conditions.

โšก
Electric Furnace Heating Element Replacement

Replace failed heating elements in electric furnaces, test all elements and sequencers before partial replacement.

โšก
Electric Heating Sequencer Replacement

Replace failed sequencers that stagger heating element startup to prevent circuit overload.

๐Ÿ”ฅ
Pilot Tubing Replacement

Replace cracked or blocked pilot tubing on older standing pilot furnaces and boilers.

๐Ÿ”ฅ
Standing Pilot Light Repair

Repair standing pilot assembly issues on older furnaces, thermocouple, pilot orifice, and gas valve.

๐Ÿ”ง
Main Gas Shutoff Valve Replacement

Replace corroded or leaking main gas shutoff valves at HVAC equipment.

Outdoor Unit & Noise Components

๐Ÿ”‡
Outdoor Unit Sound Blanket Installation

Install compressor sound blankets to reduce outdoor unit noise, particularly useful in Georgetown's zero-lot-line neighborhoods.

๐Ÿ”‡
AC Vibration Isolation Pad Replacement

Replace deteriorated equipment pads and isolation mounts that transmit vibration through slabs and walls.

Giving an Aging Compressor Extra Starting Torque

A hard start kit adds a start capacitor and a current-sensing potential relay to a compressor circuit that originally used only a run capacitor for starting assistance. The added start capacitor delivers a brief, much stronger jolt of starting torque during the initial moment the compressor motor engages, and the potential relay then disconnects that start capacitor from the circuit within a fraction of a second once the motor reaches operating speed, since leaving a start capacitor continuously energized would quickly overheat it.

This upgrade makes the most sense in a few specific situations: an aging compressor whose internal mechanical resistance has increased slightly with wear, making the standard run capacitor's starting torque marginal rather than comfortably adequate, a system with an unusually long refrigerant line run between the indoor and outdoor units, which increases the pressure differential the compressor has to overcome on startup, or a household on the edge of a service where visible light dimming occurs briefly every time the AC compressor kicks on, a hard start kit reduces that inrush current draw and the resulting voltage sag.

We diagnose whether a hard start kit is appropriate by measuring the compressor's actual starting amperage, locked rotor amps, against its rated specification, and by checking supply voltage during a start attempt to quantify any sag. A compressor drawing meaningfully elevated locked rotor amperage relative to spec, especially paired with a hesitant or delayed start, hums for a moment before catching, is a good candidate for a hard start kit as a way to extend its remaining service life rather than replacing the compressor outright.

Installation involves wiring the potential relay and start capacitor into the existing circuit alongside the run capacitor, verifying the relay's pickup and dropout voltage settings are correctly matched to the system's specific run capacitor and compressor combination, and confirming after installation that starting amperage has measurably improved and that the start capacitor is properly disconnecting once the compressor reaches run speed, a relay that fails to disconnect the start capacitor will quickly burn it out and can also stress the run capacitor and compressor motor.

It's worth being clear that a hard start kit is a targeted assist for a specific situation, not a universal upgrade every system benefits from, and we only recommend it after confirming the actual starting amperage and voltage data support it, rather than installing one reflexively on every service call.

Frequently Asked Questions, Hard Start Kit Installation

How do I know if my system actually needs a hard start kit? +
We measure locked rotor amperage during startup against the compressor's rated specification and check for supply voltage sag during that same moment. A compressor drawing elevated starting amperage or showing a hesitant, delayed start is a good candidate, but we base the recommendation on actual measurements, not assumption.
Does a hard start kit extend compressor life? +
It can, particularly on an aging compressor with slightly increased internal resistance, by reducing the mechanical and electrical stress of each start cycle. It's not a fix for a compressor that's already failing mechanically, but it can meaningfully help one that's simply starting harder than it used to.
Why do my lights dim briefly when my AC starts? +
This is caused by the momentary high inrush current, called locked rotor amperage, that a compressor draws for a fraction of a second on startup, which can cause a brief voltage sag on the electrical circuit. A hard start kit reduces that inrush current and can lessen or eliminate the dimming.
What happens if the potential relay fails to disconnect the start capacitor? +
The start capacitor would remain energized continuously instead of only during the brief start cycle, which quickly overheats and destroys the capacitor and can add unnecessary electrical stress to the run capacitor and compressor motor. We verify proper relay disconnection as part of every installation.
Is a hard start kit the same thing as a start capacitor? +
No, a hard start kit includes both a start capacitor and a potential relay that automatically disconnects it after startup. A start capacitor alone, without the relay, isn't safely usable on a continuously running compressor circuit.

Need a Component Diagnosed or Replaced?

We test before we replace. Most parts are on the truck for same-day service.

๐Ÿ“ž Call Now
(512) 798-8094