๐Ÿ“ Serving Georgetown, TX & Williamson County Mon-Sat 7AM-8PM ยท Sun 9AM-5PM | (512) 798-8094 | โšก Same-Day Service Available
Technicians Available in Georgetown
Same-Day Slots Open
Dispatch: Georgetown TX, not Austin
Average response: 45-90 min
๐Ÿ”ฉ Georgetown TX ยท Same-Day Available

๐Ÿ”ง AC Compressor Replacement, Georgetown TX

Most HVAC failures come down to a specific component, a capacitor burned out by Georgetown's heat, a contractor pitted from cycling, a blower motor bearing that's been failing for months. ProAir Georgetown carries the most common replacement components on every service truck so we can complete repairs same-day instead of ordering parts and scheduling a return visit.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

HVAC Components We Repair & Replace, Georgetown TX

Motors & Fans

๐Ÿ”ง
Blower Motor Repair

Diagnose and repair indoor blower motor failures, bearing wear, winding failure, and capacitor issues.

๐Ÿ”„
AC Blower Motor Replacement

Replace failed indoor blower motors, we stock common motors for Carrier, Trane, Lennox, Goodman, and Rheem.

๐Ÿ’ง
Blower Motor Bearing Lubrication

Lubricate blower motor bearings before they fail, catches motors that squeal before they burn out.

๐Ÿงน
Furnace Blower Wheel Cleaning

Clean blower wheels coated with dust and debris that reduce airflow and strain the motor.

๐Ÿ”ง
Fan Motor Repair

Repair or replace condenser fan motors, outdoor fan failure causes compressor overheating on Georgetown's 100ยฐF days.

โšก
Condenser Fan Motor Repair

Diagnose and repair outdoor condenser fan motor failures, common cause of AC shutdown in peak summer heat.

๐Ÿ”„
Outdoor Fan Blade Replacement

Replace cracked, bent, or imbalanced outdoor fan blades causing vibration and motor strain.

Capacitors & Contactors

โšก
Capacitor Replacement

The #1 Georgetown summer repair. Capacitors overheat and fail in sustained 100ยฐF+ heat, fast, affordable fix.

๐Ÿ”
AC Capacitor Testing & Replacement

Test capacitors before replacing, an out-of-spec capacitor causes the same symptoms as a failed compressor.

โšก
Run Capacitor Replacement

Replace failed run capacitors on compressors and fan motors, the most common summer AC component failure.

โšก
Start Capacitor Replacement

Replace start capacitors that provide the extra torque needed to start compressors on hot days.

๐Ÿ”‹
Hard Start Kit Installation

Install hard start kits on aging compressors to reduce starting current and extend compressor life.

๐Ÿ”Œ
Contactor Replacement

Replace pitted or failed contactors, the relay that connects power to the compressor and condenser fan.

๐Ÿ”Œ
AC Contactor Replacement

Replace AC contactors with pitted contacts that cause intermittent power to compressor and outdoor fan.

Compressor Service

๐Ÿ”ง
Compressor Repair

Diagnose compressor failures, not every compressor problem requires replacement. We test before recommending replacement.

๐Ÿ”„
AC Compressor Replacement

Compressor replacement with full circuit flush, filter drier, evacuation, and recharge, done correctly to protect the new compressor.

๐Ÿ”‡
AC Muffler Repair

Replace discharge mufflers that reduce compressor noise and protect the refrigerant circuit.

๐Ÿ”ฅ
Compressor Crankcase Heater Installation

Install crankcase heaters to prevent refrigerant migration into compressor oil during cold Texas nights.

โฌ†๏ธ
High Pressure Switch Replacement

Replace failed high-pressure safety switches that protect compressors from dangerously high discharge pressure.

โฌ‡๏ธ
Low Pressure Switch Replacement

Replace low-pressure safety switches that prevent compressor damage from loss of refrigerant charge.

Furnace Components

โฌ†๏ธ
High Limit Switch Replacement

Replace failed high-limit switches that shut furnaces down on overheating, essential safety component.

๐Ÿ–ฅ๏ธ
Furnace Control Board Replacement

Replace faulty furnace control boards, we test all connected components first to confirm the board is the failure.

๐Ÿ”ง
Furnace Fan Control Switch Repair

Repair or replace fan control switches that govern blower timing in older furnaces without electronic control boards.

๐Ÿ”ฅ
Furnace Hot Surface Ignitor Replacement

Replace fragile silicon carbide or silicon nitride ignitors, the #1 furnace no-heat repair in Georgetown.

๐Ÿ”ฅ
Furnace Flame Sensor Replacement

Replace or clean flame sensors that fail to detect the burner flame, causing furnace lockout.

๐Ÿ”ง
Furnace Gas Valve Replacement

Replace failed gas valves that prevent gas flow to burners, verified diagnosis before replacement.

๐ŸŒก๏ธ
Furnace Thermocouple Replacement

Replace thermocouples on older standing pilot furnaces that fail to keep the pilot lit.

๐Ÿ”’
Furnace Rollout Switch Replacement

Replace tripped rollout switches, but also diagnose why flames rolled out, as this indicates a serious underlying condition.

๐Ÿ’จ
Draft Inducer Motor Replacement

Replace failed draft inducer motors in 80%+ efficiency furnaces, failure causes pressure switch trips and no-heat conditions.

โšก
Electric Furnace Heating Element Replacement

Replace failed heating elements in electric furnaces, test all elements and sequencers before partial replacement.

โšก
Electric Heating Sequencer Replacement

Replace failed sequencers that stagger heating element startup to prevent circuit overload.

๐Ÿ”ฅ
Pilot Tubing Replacement

Replace cracked or blocked pilot tubing on older standing pilot furnaces and boilers.

๐Ÿ”ฅ
Standing Pilot Light Repair

Repair standing pilot assembly issues on older furnaces, thermocouple, pilot orifice, and gas valve.

๐Ÿ”ง
Main Gas Shutoff Valve Replacement

Replace corroded or leaking main gas shutoff valves at HVAC equipment.

Outdoor Unit & Noise Components

๐Ÿ”‡
Outdoor Unit Sound Blanket Installation

Install compressor sound blankets to reduce outdoor unit noise, particularly useful in Georgetown's zero-lot-line neighborhoods.

๐Ÿ”‡
AC Vibration Isolation Pad Replacement

Replace deteriorated equipment pads and isolation mounts that transmit vibration through slabs and walls.

The Full Process Behind a Proper Compressor Swap

The compressor is the heart of your refrigerant circuit, it compresses low pressure vapor refrigerant into a high pressure, high temperature gas so the system can reject heat outside and absorb it inside. When a compressor fails completely, whether from a burned winding, a mechanically seized scroll, or a valve failure on an older reciprocating unit, the entire circuit has to be properly cleared and protected before a new compressor goes in, simply bolting in a new compressor without the supporting steps is the most common reason replacement compressors fail again within the first year.

Our process starts with recovering the remaining refrigerant, cutting out the failed compressor, and inspecting the line set and oil for signs of an electrical burnout, indicated by a strong acidic odor and dark, sludgy oil. If burnout contamination is present, we flush the line set with an appropriate solvent and install a suction line filter drier in addition to the standard liquid line drier to catch acid and debris that could otherwise destroy the new compressor within weeks. We braze in the new compressor, pressure test the circuit with dry nitrogen to check for leaks, then pull a deep vacuum, typically to 500 microns or lower, to remove moisture and non-condensable air before weighing in the correct refrigerant charge by manufacturer specification.

Many Georgetown homes built in the 1990s and 2000s still run systems originally charged with R-22, which has not been produced for new equipment in years and is now expensive when it can be found at all. If your compressor has failed on an older R-22 system, we will walk through whether a compatible replacement compressor and a like-for-like R-22 recharge still makes financial sense, or whether the age of the rest of the system means a full changeover to a new R-410A system is the better long-term investment.

We also test the capacitor, contactor, and supply voltage before ever condemning a compressor, since a weak capacitor or failing contactor can present with symptoms nearly identical to compressor failure, humming without starting, tripped breakers, or hard starting. Confirming the compressor is truly the failed component, rather than assuming it, saves homeowners from paying for a compressor that was never actually the problem.

Frequently Asked Questions, AC Compressor Replacement

Do you flush the line set every time you replace a compressor? +
Only when there is evidence of electrical burnout, dark or acidic oil residue. A clean mechanical failure with normal oil does not require a full flush, but we always install a fresh filter drier regardless to protect the new compressor from residual moisture or debris.
What if my system still uses R-22 refrigerant? +
We will check whether a compatible compressor is still available and discuss current R-22 pricing and availability with you honestly. On older R-22 systems, replacing just the compressor is sometimes not the most cost effective path compared to a full system upgrade, and we'll lay out both options.
How deep do you pull vacuum before recharging? +
We pull to 500 microns or lower using a calibrated micron gauge, not just a compound gauge reading zero. Skipping a proper deep vacuum leaves moisture in the system that can freeze at the metering device or form acid that attacks the new compressor.
Could my compressor problem actually be something else? +
Often, yes. We test the capacitor, contactor, and incoming voltage before condemning the compressor, since those cheaper components frequently mimic compressor failure symptoms like humming, hard starting, or tripped breakers.
Is compressor replacement covered under warranty? +
If your compressor is still within the manufacturer's parts warranty period, we handle the warranty claim process and you generally only pay for labor, refrigerant, and any required line set work. We verify warranty eligibility using your unit's serial number before starting the job.

Need a Component Diagnosed or Replaced?

We test before we replace. Most parts are on the truck for same-day service.

๐Ÿ“ž Call Now
(512) 798-8094