Most HVAC failures come down to a specific component, a capacitor burned out by Georgetown's heat, a contractor pitted from cycling, a blower motor bearing that's been failing for months. ProAir Georgetown carries the most common replacement components on every service truck so we can complete repairs same-day instead of ordering parts and scheduling a return visit.

๐Ÿ“ž Call (512) 798-8094 Schedule Online
๐Ÿ›ก๏ธTX HVAC Licensed (TDLR)
๐Ÿ›ก๏ธTX Licensed & NATE Certified
โšกSame-Day Dispatch
Same Day
Service Available
1-Year
Parts & Labor Warranty
1-Yr
Parts & Labor Warranty
TX Licensed
TDLR Regulated

HVAC Components We Repair & Replace, Georgetown TX

Motors & Fans

๐Ÿ”ง
Blower Motor Repair

Diagnose and repair indoor blower motor failures, bearing wear, winding failure, and capacitor issues.

๐Ÿ”„
AC Blower Motor Replacement

Replace failed indoor blower motors, we stock common motors for Carrier, Trane, Lennox, Goodman, and Rheem.

๐Ÿ’ง
Blower Motor Bearing Lubrication

Lubricate blower motor bearings before they fail, catches motors that squeal before they burn out.

๐Ÿงน
Furnace Blower Wheel Cleaning

Clean blower wheels coated with dust and debris that reduce airflow and strain the motor.

๐Ÿ”ง
Fan Motor Repair

Repair or replace condenser fan motors, outdoor fan failure causes compressor overheating on Georgetown's 100ยฐF days.

โšก
Condenser Fan Motor Repair

Diagnose and repair outdoor condenser fan motor failures, common cause of AC shutdown in peak summer heat.

๐Ÿ”„
Outdoor Fan Blade Replacement

Replace cracked, bent, or imbalanced outdoor fan blades causing vibration and motor strain.

Capacitors & Contactors

โšก
Capacitor Replacement

The #1 Georgetown summer repair. Capacitors overheat and fail in sustained 100ยฐF+ heat, fast, affordable fix.

๐Ÿ”
AC Capacitor Testing & Replacement

Test capacitors before replacing, an out-of-spec capacitor causes the same symptoms as a failed compressor.

โšก
Run Capacitor Replacement

Replace failed run capacitors on compressors and fan motors, the most common summer AC component failure.

โšก
Start Capacitor Replacement

Replace start capacitors that provide the extra torque needed to start compressors on hot days.

๐Ÿ”‹
Hard Start Kit Installation

Install hard start kits on aging compressors to reduce starting current and extend compressor life.

๐Ÿ”Œ
Contactor Replacement

Replace pitted or failed contactors, the relay that connects power to the compressor and condenser fan.

๐Ÿ”Œ
AC Contactor Replacement

Replace AC contactors with pitted contacts that cause intermittent power to compressor and outdoor fan.

Compressor Service

๐Ÿ”ง
Compressor Repair

Diagnose compressor failures, not every compressor problem requires replacement. We test before recommending replacement.

๐Ÿ”„
AC Compressor Replacement

Compressor replacement with full circuit flush, filter drier, evacuation, and recharge, done correctly to protect the new compressor.

๐Ÿ”‡
AC Muffler Repair

Replace discharge mufflers that reduce compressor noise and protect the refrigerant circuit.

๐Ÿ”ฅ
Compressor Crankcase Heater Installation

Install crankcase heaters to prevent refrigerant migration into compressor oil during cold Texas nights.

โฌ†๏ธ
High Pressure Switch Replacement

Replace failed high-pressure safety switches that protect compressors from dangerously high discharge pressure.

โฌ‡๏ธ
Low Pressure Switch Replacement

Replace low-pressure safety switches that prevent compressor damage from loss of refrigerant charge.

Furnace Components

โฌ†๏ธ
High Limit Switch Replacement

Replace failed high-limit switches that shut furnaces down on overheating, essential safety component.

๐Ÿ–ฅ๏ธ
Furnace Control Board Replacement

Replace faulty furnace control boards, we test all connected components first to confirm the board is the failure.

๐Ÿ”ง
Furnace Fan Control Switch Repair

Repair or replace fan control switches that govern blower timing in older furnaces without electronic control boards.

๐Ÿ”ฅ
Furnace Hot Surface Ignitor Replacement

Replace fragile silicon carbide or silicon nitride ignitors, the #1 furnace no-heat repair in Georgetown.

๐Ÿ”ฅ
Furnace Flame Sensor Replacement

Replace or clean flame sensors that fail to detect the burner flame, causing furnace lockout.

๐Ÿ”ง
Furnace Gas Valve Replacement

Replace failed gas valves that prevent gas flow to burners, verified diagnosis before replacement.

๐ŸŒก๏ธ
Furnace Thermocouple Replacement

Replace thermocouples on older standing pilot furnaces that fail to keep the pilot lit.

๐Ÿ”’
Furnace Rollout Switch Replacement

Replace tripped rollout switches, but also diagnose why flames rolled out, as this indicates a serious underlying condition.

๐Ÿ’จ
Draft Inducer Motor Replacement

Replace failed draft inducer motors in 80%+ efficiency furnaces, failure causes pressure switch trips and no-heat conditions.

โšก
Electric Furnace Heating Element Replacement

Replace failed heating elements in electric furnaces, test all elements and sequencers before partial replacement.

โšก
Electric Heating Sequencer Replacement

Replace failed sequencers that stagger heating element startup to prevent circuit overload.

๐Ÿ”ฅ
Pilot Tubing Replacement

Replace cracked or blocked pilot tubing on older standing pilot furnaces and boilers.

๐Ÿ”ฅ
Standing Pilot Light Repair

Repair standing pilot assembly issues on older furnaces, thermocouple, pilot orifice, and gas valve.

๐Ÿ”ง
Main Gas Shutoff Valve Replacement

Replace corroded or leaking main gas shutoff valves at HVAC equipment.

Outdoor Unit & Noise Components

๐Ÿ”‡
Outdoor Unit Sound Blanket Installation

Install compressor sound blankets to reduce outdoor unit noise, particularly useful in Georgetown's zero-lot-line neighborhoods.

๐Ÿ”‡
AC Vibration Isolation Pad Replacement

Replace deteriorated equipment pads and isolation mounts that transmit vibration through slabs and walls.

Preventing Electrical Overload With Staged Heat

A heating sequencer is a time-delay relay that controls the order and timing in which multiple electric heating elements energize within an electric furnace or heat pump air handler's heat strip package. Rather than energizing every element simultaneously, which would create a massive instantaneous current draw and could trip breakers or overload household electrical service, the sequencer brings elements online one at a time, typically with a delay of 30 seconds to a couple of minutes between stages, spreading out the electrical demand.

Most sequencers use a small internal heater element that warms a bimetal strip, which then physically closes a set of contacts to energize the next stage, an elegant, purely mechanical timing mechanism that doesn't rely on any electronic logic. That mechanical simplicity is also the source of most failures, over years of heating and cooling cycles, the bimetal strip and its contacts can weaken, drift out of proper timing, or the contacts themselves can weld shut, causing a stage to stay energized when it shouldn't or fail to energize when the thermostat calls for it.

We diagnose a failing sequencer by checking its stage timing against the manufacturer's specified delay intervals and testing continuity across each set of contacts both when it should be open and when it should be closed. A sequencer with welded contacts will show a stage energized even with the thermostat satisfied, which can present as elements running continuously and driving up electric bills unexpectedly, while a sequencer with contacts that never close means one or more heating stages simply never comes on, showing up as reduced or absent heat output.

Replacement means matching the sequencer's stage count, contact ratings, and timing specification to the original part, since installing a sequencer with the wrong number of stages or an incompatible timing interval can either underpower the heating system or, in the case of a sequencer that brings elements on too quickly, create the exact overload risk the component is meant to prevent. As with heating elements generally, sequencer service in Georgetown comes up most often on heat pump backup heat strip systems given how much more common heat pumps are here than pure electric furnaces.

Frequently Asked Questions, Electric Heating Sequencer Replacement

How does a sequencer actually stagger the heating elements? +
Most sequencers use an internal heater warming a bimetal strip, which mechanically closes contacts to bring the next element online after a built-in delay, typically 30 seconds to a couple of minutes between stages. This spreads out electrical demand rather than energizing everything at once.
Can a bad sequencer cause my electric bill to spike unexpectedly? +
Yes, if the contacts weld shut in the closed position, that heating stage can stay energized continuously even after the thermostat is satisfied, running up electrical usage without your knowledge until it's diagnosed.
What happens if a sequencer's contacts never close? +
That heating stage simply never comes online, which reduces total heat output. This can be subtle on a multi-stage system, showing up as the furnace running longer to reach the same temperature rather than an obvious complete failure.
Is a sequencer an electronic component or a mechanical one? +
Most heating sequencers are purely mechanical, relying on a heater-warmed bimetal strip to physically time contact closure rather than any electronic circuitry. This makes them reliable but also means they wear out mechanically over years of cycling.
Do all electric heat systems use sequencers? +
Most multi-stage electric furnaces and heat pump heat strip packages do, since staggering elements protects against electrical overload. Single-element systems typically don't need one since there's only one stage to control.

Need a Component Diagnosed or Replaced?

We test before we replace. Most parts are on the truck for same-day service.

๐Ÿ“ž Call Now
(512) 798-8094